国产三级伦理在线,久久久久黄久久免费漫画,成人国产精品日本在线,欧美美最猛性xxxxxx

美國(guó)Hausser細(xì)胞計(jì)數(shù)板
美國(guó)Hausser細(xì)胞計(jì)數(shù)板
產(chǎn)品價(jià)格:(人民幣)
  • 規(guī)格:完善
  • 發(fā)貨地:本地至全國(guó)
  • 品牌:
  • 最小起訂量:1臺(tái)
  • 免費(fèi)會(huì)員
    會(huì)員級(jí)別:試用會(huì)員
    認(rèn)證類型:企業(yè)認(rèn)證
    企業(yè)證件:通過認(rèn)證

    商鋪名稱:江蘇明珠試驗(yàn)機(jī)械有限公司

    聯(lián)系人:李先生(先生)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:18268080050@163.com

    聯(lián)系地址:江蘇省揚(yáng)州市江都區(qū)真武工業(yè)園區(qū)

    郵編:225264

    聯(lián)系我時(shí),請(qǐng)說是在焊材網(wǎng)上看到的,謝謝!

    商品詳情

      美國(guó)Hausser細(xì)胞計(jì)數(shù)板

      美國(guó)Hausser細(xì)胞計(jì)數(shù)板(Nageotte Counting Chamber):亮線型,常用于單采血小板中的殘留白細(xì)胞的計(jì)數(shù)。池深:0.5mm。提供兩種:一種H型,中間有溝隔開為兩計(jì)數(shù)區(qū)(貨號(hào)4000),一種沒有溝槽(4001)美國(guó)Hausser scientific血球計(jì)數(shù)板,霍華德霉菌計(jì)數(shù)板,準(zhǔn)確計(jì)算白細(xì)胞、紅細(xì)胞、血小板、組織培養(yǎng)細(xì)胞、細(xì)菌和精子The Hausser Nageotte Bright-Line Hemacytometer allows one to manually count low leukocyte concentrations below the capabilities of a standard Hemacytometer. The Nageotte contains two gridded counting areas each containing 40 rectangular areas. Total volume of each grid is 50 mL for a total volume of 100 mL per Nageotte. The Nageotte can accuray measure down to 0.1 cell/mL (100 cell/ml). Cell Depth is 0.5mm .

      美國(guó)Hausser細(xì)胞計(jì)數(shù)板

      Available with an H-shaped moat(catalog#4000) that separates the two gridded areas or without a moat (catalog#4001). The Nageotte Chamber comes with two reusable cover slips(30mm X 33mm X 0.5mm) and 1/2 oz (approx. 35 pcs.) of disposable cover slips (30mm X 33mm X 0.15mm). PROCESS: Counting low levels of white cells in white cell-reduced plaetcomponents.BACKGROUND: Determination of the white cell (WBC) count in WBC-reduced plaet components requires methods that have a detection limit in the range of approximay 5.0 x 10(2) to 5.0 x 10(4) per mL.STUDY DESIGN AND METHODS: With a 50-microL Nageotte hemocytometer and bright-field microscopy (200x magnification), studies were conducted to develop and validate a method that could be used routinely with filtered and apheresis-harvested plaets. A 1-in-5 dilution of sample with a commercially available blood-diluting fluid was used because, with a lower (1-in-2) dilution, the observed number of WBCs was substantially less than the number expected at relatively high plaet counts (> 1.9 x 10(9)/mL). RESULTS: The observed and expected WBC counts in WBC-reduced plaet samples correlated well at levels between approximay 5 and 1100 WBCs per counting area (5.0 x 10(2)-1.1 x 10(5)/mL). At levels of more than 300 to 400 WBCs per counting area, accurate counts were obtained when 10 of the 40 rectangles were counted.


      http://www.shheyukj.com/Products-28067542.html
      http://www.chem17.com/st357451/erlist_2167798.html

    在線詢盤/留言
  • 0571-87774297  
    主站蜘蛛池模板: 临高县| 巍山| 舒兰市| 定日县| 盖州市| 东丰县| 马尔康县| 乐业县| 锡林浩特市| 内黄县| 龙泉市| 金山区| 云龙县| 富宁县| 宣汉县| 天门市| 康乐县| 广元市| 南陵县| 横山县| 达拉特旗| 嘉定区| 汽车| 周口市| 开平市| 连南| 郧西县| 武邑县| 吉安市| 岳池县| 呼和浩特市| 青川县| 林州市| 山丹县| 和田市| 镇巴县| 开远市| 玉溪市| 阳信县| 锦屏县| 梁平县|