国产三级伦理在线,久久久久黄久久免费漫画,成人国产精品日本在线,欧美美最猛性xxxxxx

keyence fs v11
keyence fs v11
產(chǎn)品價(jià)格:¥1(人民幣)
  • 規(guī)格:keyence fs v11
  • 發(fā)貨地:蘇州
  • 品牌:
  • 最小起訂量:1套
  • 誠信商家
    會(huì)員級(jí)別:金牌會(huì)員
    認(rèn)證類型:企業(yè)認(rèn)證
    企業(yè)證件:通過認(rèn)證

    商鋪名稱:蘇州捷士佳自動(dòng)化設(shè)備有限公司

    聯(lián)系人:任國(guó)強(qiáng)(先生)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:954508046@qq.com

    聯(lián)系地址:江蘇省蘇州市相城大道168號(hào) 新尚廣場(chǎng)A座901室

    郵編:215300

    聯(lián)系我時(shí),請(qǐng)說是在焊材網(wǎng)上看到的,謝謝!

    商品詳情

      Amplifier specifications   FS-V11 FS-V12 FS-V10

      1.
      NPN FS-V11 FS-V12 FS-V10
      Model
      PNP FS-V11P FS-V12P
      Light source Red LED
      2.
      Response time 250 μs (FINE)/500 μs (TURBO) / 1 ms (SUPER TURBO) 410 μs to 1.7 ms
      Operation mode LIGHT-ON/DARK-ON (switch-selectable)
      Output indicator: Red LED
      Digital LED monitor: Red LED
      3.
      Indicators
      Bar graph LED monitor: Green/Orange LED 
      3.
      Calibration indicator: Orange LED 
      Timer function OFF-delay: 40 ms, 10 ms / Timer OFF (switch selectable)
      Control output NPN or PNP open-collector: 100 mA (40 V max.), Residual voltage: 1 V max.
      Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
      Power supply voltage 12 to 24 VDC±10%, Ripple (P-P) 10% max.
      Current consumption 50 mA max.
      Ambient illumination Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
      4.
      Ambient temperature -10 to +55 °C
      Relative humidity 35 to 85%
      Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions for two hours.

      Shock immunity 500 m/ s in X, Y, and Z directions, three times each.
      Housing material Body/Cover: Polycarbonate
      Weight (including 2-m cable) Approx. 80 g  Approx. 45 g Approx. 20 g
      1.FS-V10 has no output wire and FS-R0 should be used for  issuing output.
      2.The response time varies depending on the number of expansion units connected.
      3.The orange LED is normally part of the bar graph LED monitor. It is used as a calibration indicator during the setting of the sensitivity.
      4. When several units are connected, the allowable ambient temperature changes depending on the following conditions.
         To connect several units, be sure to mount them to a DIN rail (metal DIN rail). Make sure that the output current is 20 mA max.
            When 3 to 10 units are connected: -10 to +50°C
            When 11 to 16 units are connected: -10 to +45°C