国产三级伦理在线,久久久久黄久久免费漫画,成人国产精品日本在线,欧美美最猛性xxxxxx

美國vanguard RFD-200 S3數字計時器
美國vanguard RFD-200 S3數字計時器
產品價格:(人民幣)
  • 規格:RFD-200 S3
  • 發貨地:上海
  • 品牌:
  • 最小起訂量:1件
  • 誠信商家
    會員級別:鉆石會員
    認證類型:企業認證
    企業證件:通過認證

    商鋪名稱:上海山合海融商貿有限公司

    聯系人:孫寶金(先生)

    聯系手機:

    固定電話:

    企業郵箱:sh@51082245.com

    聯系地址:上海市寶山區陸翔路678弄60號

    郵編:201907

    聯系我時,請說是在焊材網上看到的,謝謝!

    商品詳情

      The RFD-200 S3 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessor-based protective relays in their operating installations. The RFD-200 S3 is a rugged test set suitable for testing a variety of protection relays operated in both indoor and outdoor environments. The unit’s ergonomic design and intuitive control panel layout make it ideal for first-time users who have little or no training.


      • A built-in Timer displays contact time in both cycles and milliseconds
      • AC current source with 3 outputs (10A, 40A, 100A)
      • Set of NO/NC dry contacts that change state when a test is initiated
      • AC voltage source for testing relays up to 250 Vac
      • DC Voltage source (0 - 300 Vdc)
      • Volt meter input (0 - 600 V input range)
      • Three power supplies (24 Vdc, 48 Vdc, 124 Vdc)
      • Built-in power resistors

      RFD-200 S3

      Cables

       
             
             

      RFD-200 S3

      Technical Specifications

       
             
      TYPE Portable relay test set
      INPUT POWER 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
      PHYSICAL SPECIFICATIONS 17”W x 12.5”H x 12”D, (42.7 cm x 32.0 cm x 30.5 cm); Weight: 35 lbs (15.9 kg)
      AMPERE METER INPUT RANGES Internal input range: 0 – 250 A; Accuracy: 2% of reading ± 10 mA,
      External AC input range: 0 – 6A; Accuracy: 1% of reading ± 10mA
      External DC input range: 0 – 6A; Accuracy: 0.5% of reading ±1 count
      Measurement Method: True RMS for AC
      VOLT METER INPUT RANGE 0 – 600.0V; AC accuracy: 1% of reading ±1 count; DC accuracy 0.5% of reading ±1 count
      Measurement Method: True RMS for AC
      AUXILIARY POWER SUPPLIES 24 Vdc @ 1 A, 48 Vdc @ 0.25 A, 124 Vdc @ 0.125 A
      POWER RESISTORS 5 Ω/50 W, 1 Ω/50 W, 25 Ω/50 W, 100 Ω/50 W, 500 Ω/50 W
      SAFETY Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards
      ENVIRONMENT Operating: -10?C to 50? C (15?F to +122? F); Storage: -30? C to 70? C (-22?F to +158? F)
      OPTIONS Transportation case
      WARRANTY One year on parts and labor
      AC Current Output
      Range No-Load Voltage Load Voltage Load Current Load/Unload Times
      10 A 90 Vac 75 Vac 10 A 2 min / 15 min
      40 A 25 Vac 20 Vac 40 A 1 min / 15 min
      100 A 10 Vac 7.25 Vac 100 A 1 min / 15 min
      100 A 10 Vac 3 Vac 250 A 1 sec / 5 min
      AC Voltage Output
      Range No-Load Voltage Load Voltage Load Current Load/Unload Times
      250 Vac 260 Vac 240 Vac 3 A 10 min / 45 min
      DC Voltage Output
      Range No-Load Voltage Load Voltage Load Current Load/Unload Times
      300 Vdc 300 Vdc 250 Vdc 2 A 10 min / 45 min
      RFD-200 Timer Second Display In seconds and cycles (50/60 Hz programmable)
      Range Resolution Accuracy
      0 to 9.999 sec 1 ms ± (1 ms + 0.01%)
      10.00 to 99.99 sec 10 ms ± (10 ms + 0.01%)
      100.0 to 999.999 sec 100 ms ± (100 ms + 0.01%)
      Timer Cycles Display
      Range Resolution Accuracy
      0 to 9.999 cycles 0.1 cycle ± (0.1 cycle + 0.01%)
      1,000 to 49,999 cycles / 50 Hz 1 cycle ± (1 cycle + 0.01%)
      Specifications are valid at nominal voltage and ambient temperature of +25?C (+77?F).