MG7/50-G25 AQ1PGG 023780000--Burgmann
Connection cable for AS 2000; for connection between PC and fire alarm panel
(AS?SYSUTILPAC includes this item)
116-XGE-1/10-XX Ribbon cable. Optional lengths: 40 or 110 cm. Replace XX with length
116-XL-073 Conversion cable from AutroSafe 3 to AutroSafe 4
Relays
Part number Description
116-7624-030.0001 Relay PLC RSC 24 DC/21, single change-over contact
116-7624-030.0002 Relay PLC RSC 24 DC/21-21, double change-over contact
Customer configuration
Part number Description
116-PROG-AUTROSAFE Customer specific software for AutroSafe
116-TXT-AUTROSAFE Customer texts/controls
20 Autronica Fire and Security AS, Petrochemical, Oil & Gas 21
PRODUCTS 2016
AutroMaster presentation system
AutroMaster editions
AutroMaster ISEMS is the complete AutroMaster edition, including all functionality. In addition, we offer a market specific edition with the modules most
relevant for the oil and gas market
Modules/functions
AutroMaster
POG edition
AutroMaster
ISEMS
Basic functionality
Fire management basic functions ? ?
MultiSensor control ? ?
Report generator ? ?
Control and monitoring of emergency lights/LLL ? ?
Extended functionality
AutroSafe IFG unit support ? ?
Touch screen support ? ?
Decision support system/incident manager ?
Electronic plotting table ?
Training/simulation module ?
Event record and replay module ?
Video module (live video support CCTV) ? ?
Remote connect function ?
Message centre module ?
Interfaces
Hernis CCTV interface ?
System-S interface ?
NMEA interface ?
VDR output ?
MODBUS interface ?
ESPA 4.4.4 interface ?
AutroMaster presentation system
A fully integrated safety and emergency management system
The AutroMaster is an integrated safety and emergency management
system combining the strengths of a powerful fire detection system with
control and monitoring functions dedicated to make sure you are in
control in case of an emergency.
Graphical user interface
The AutroMaster provides an intuitive control and monitoring interface
built to save valuable time when every second counts. Status information is
displayed in real-time with easy-to-understand graphical representation.
Navigation is fast and instinctual and the powerful zoom functions allow
you to monitor all areas in great detail.
AutroMaster displays values for smoke density and heat in dynamic colours,
making it easy to perform the necessary actions during emergencies.
Interoperability
Control and monitoring of third party systems can easily be performed via
serial protocols or network interfaces. They provide connection to basically
any source – network time servers, telephone systems for text messaging,
public address systems for automated voice messaging, emergency lights,
access control systems, CCTV, automation systems and so on.
Logging and reporting
The AutroMaster keeps track of all events in the system and has a built-in
report generator. This provides a cost-effective system log for maintenance
and documentation purposes.
Decision-making tools
In high-risk environments around the world, a seemingly innocuous
fire can quickly escalate into an emergency of large proportions. When
disaster strikes and you only have seconds to make the proper decisions,
the right safety and emergency management system is an invaluable
asset. The AutroMaster includes a Decision Support System (DSS) that will
help you make the right decisions at the right time.
Easy to use,
provides full overview
and saves valuable time
22 Autronica Fire and Security AS, Petrochemical, Oil & Gas 23
PRODUCTS 2016
AutroMaster presentation system
Interface modules
Software licences
Part number Description
116-PROG-AUTROMASTER-POG
AutroMaster Oil & Gas Edition – For the Petrochemical, Oil and Gas market applications, support for the SIL2
approved AutroSafe IFG panel is mandatory. The AutroMaster Oil & Gas Edition is specially designed to use the
AutroSafe IFG functionality to among other functions provide gas trending and LEL indication.
116-PROG-AUTROMASTERISEMS
AutroMaster ISEMS – Provides the full range of functionality – every possible add-on module is included
in this package, making it the perfect choice for demanding applications and professional customers.
116-PROG-AM-UPGRADE
Upgrade of AutroMaster to most recent version – Existing AutroMaster customers can upgrade their
license to the most recent version of AutroMaster. Requires change of AutroMaster configuration data.
Software modules
Part number Description
116-PROG-AM-MOD-DSS
Decision Support System (DSS) – An interactive incident management system for AutroMaster. The DSS
gives operators access to customer-specified checklists. The checklists are organized as checkpoints with
one or more action items that can be used to manage operations, and these can be marked off as actions
are completed.
116-PROG-AM-MOD-EPTABLE
Electronic fire control plotting table – gives you a dynamic plotting table to keep track of actors events
during an emergency or drill. All EPT activity is logged in the Decision Support System and is available for
later reviews.
116-PROG-AM-MOD-TSIM
Training/Simulation module – A tool to simulate pre-configured events. During a simulation it is possible
to pause, stop/end, and continue the simulation. Running the simulation tool is similar to running a live
event, alarms and faults are acknowledgeable and resettable. Every event is logged, and after a simulation
(or a stop), a full log can created and it is possible to replay the simulation using the Event record/replay
module.
116-PROG-AM-MOD-EVENT
Event Record/Replay module – Offers a screenshot-based replay of incidents on AutroMaster and can be
configured to start recording manually or on pre-configured events as pre-warning, alarm or simulation.
Recordings are available for replay, and under replay the operator can start, stop, pause, fast-forward and
fast backwards. It is possible to export stored events.
116-PROG-AM-MOD-VIDEO Video interface module – Includes display of live video in AutroMaster from IP based video cameras.
116-PROG-AM-MOD-REMOTE
Remote Connect function – The Remote Connect Module enables a remote connection to AutroMaster
from any location using a server/client technology.
116-PROG-AM-MOD-MC
Message Centre module – In the Message Centre the user can send text messages to telephone systems
and other AutroMaster PCs. The user can also send pre-recorded voice messages to PA systems. Requires
ESPA 4.4.4. interface.
Interface modules
Part number Description
116-PROG-AM-MOD-HERNIS
Hernis CCTV interface – Interface enables use of AutroMaster together with video cameras and servers
from Hernis.
116-PROG-AM-MOD-NMEA
NMEA interface – A protocol used for interface in between maritime electronic equipment, and
AutroMaster has built-in support for this in the NMEA interface module. Interface towards GPS is the most
common application.
116-PROG-AM-MOD-VDROUTPUT
VDR output – Used in maritime applications for giving output to the Voyage Data Recorder. Configuration
of which data and status messages to send to the VDR is done by project engineering.
116-PROG-AM-MOD-MODBUS
MODBUS interface – With the MODBUS interface AutroMaster can be connected to almost any kind of
electronic equipment for monitoring and control.
116-PROG-AM-MOD-ESPA444
ESPA 4.4.4 interface – Offers a serial protocol intended for the interconnection of paging equipment with
telephone exchanges or computer systems. The protocol used is message-based and is built upon the
ISO1745 transport specification. Required if Message Centre module is used.
Software hardcopies
Part number Description
116-AUTROMASTER-POG-CD AutroMaster POG back-up CD without licence
116-AUTROMASTERISEMS-CD AutroMaster ISEMS back-up CD without licence
Engineering
Part number Description
116-PROSJAMD Adding of detectors to drawings
116-PROSJAMDF Adding of color fill for analog values
24
Hardware
Part number Description
116-AUTROMASTER-PC-11 PC , desktop version, convertible minitower. Model subject to change without prior notice.
116-AUTROMASTER-RACKPC 19" rack mounted PC
116-5151-020.0210 Industrial PC w/SSD
116-5151-020.1951 19" standard LCD monitor (1280 x 1024 resolution)
116-5151-020.2405 24" widescreen LCD monitor (1920 x 1200 resolution)
116-5151-200.0023 20” monitor, console mounted, JH20T17 MMD
116-5151-017.0002 Keyboard - UK/English character set
116-5151-020.0400 Mouse - USB - 3 buttons
116-5760-050.2003 Laser printer, colour, network and USB
116-5151-020.0732 Network card TG-3468 10/100/1000
116-5151-020.2029 Moxa 4-port serial PCIE
26 Autronica Fire and Security AS, Petrochemical, Oil & Gas 27
PRODUCTS 2016
Loop units
Input and output units
Input and output units
AutroSafe offers a wide range of input and output units for many different applications. The system features Exn-, Exia- and Exd approved input and output units for
high risk applications. All input and output units feature automatic addressing and short-circuit protection.
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection
level**
Notes
116-BN-180 AutroKeeper ? IP30
Use two units to access
one loop from two loop
controllers.
DIN rail mounting in
cabinet.
116-BN-201 Monitoring unit ? ? 1/0 ?
IP54
IP67
For external units
116-BN-221/01
Extinguishing control
unit
? ? 2/1 ? ? IP67
116-BN-221/02
Output unit with
7 A relay
? 0/1 ? ? IP67 Loop controlled FAD unit
116-BN-300 Input unit ? ? 1/0 ? ?
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
116-BN-300M Modular input unit ? ? 1/0 ? ? Mounting on TS-35 rail
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
We provide a wide range of loop units for our fire detection systems. Our
detectors, manual call points, I/O units, control units and alarm units are
developed and approved according to European directives (CPD) requiring
EN 54 compliance and other appropriate worldwide regulations.
The loop units are available both with and without SelfVerify function.
SelfVerify solves all issues of manual maintenance, leaving time consuming
and costly physical testing redundant. With AutroSafe SelfVerify?, the
system checks all detectors, interfaces, connections and cables – from
detector chamber to alarm output – every single day.
Not only does the system test whether a detector is capable of provoking
an alarm, it even verifies the sensitivity of every detector with a calibrated
signal. The SelfVerify system ensures that each detector always responds
to the correct alarm level. In the event of irregularities, the display on the
operating panel will accurately pinpoint the source of any problem.
SelfVerify ensures that you have the safest and most reliable fire safety
system available – a system ensuring optimal detection.
Loop units
A wide range covering your basic fire detection needs
SelfVerify ensures
optimal detection
28 Autronica Fire and Security AS, Petrochemical, Oil & Gas 29
PRODUCTS 2016
Loop units
Input and output units
Input and output units (cont.)
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-303
Single monitored
input unit
? ? 1/0 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-304 Input/output unit ? ? ? 1/1 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-305
Dual monitored input/
output unit
? ? ? 2/2 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals (Not
SIL2/FM/USCG)
116-BN-307
Monitored Fire Alarm
Device Control Unit
? 0/1 ? ?
IP54
IP67
Limited approvals (Not
SIL2/FM/USCG)
116-BN-310 Relay output unit 0/1 ? ?
IP54
IP67
116-BN-320 Interface unit ? ? 2/1 ? ?
IP54
IP67
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
Input and output units (cont.)
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-320/2 Door control unit ? 2/1 ? ?
IP54
IP67
116-BN-320/4 Standard control unit ? 2/1 ? ?
IP54
IP67
Control of external equipment
116-BN-320/5
Sprinkler monitoring
unit
? 1/0 ? ?
IP54
IP67
116-BNB-330A
Loop adapter unit for
conventional loops
? 1/1 ? ? IP20
Replacement unit for BNB-
330 in existing AutroSafe 3
systems
116-BNB-331
Loop adapter unit for
conventional loops
? 1/1 ? ? IP20 AutroSafe ver. 4.4.1 ?
116-BN-500/EX Input unit ? ? 1/0 ? ? ?
IP54
IP67
For interfacing external units,
clean contacts, alarm relays,
etc.
Zones 0, 1 & 2
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
30 Autronica Fire and Security AS, Petrochemical, Oil & Gas 31
PRODUCTS 2016
Loop units
Control units
Input and output units (cont.)
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-500/N Input unit ? ? 1/0 ? ?
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
Zone 2
116-BN-505/EXD
Input unit with BNB-
300
? ? 1/0 ? ? IP66 Zones 1 & 2 only
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
Control units
AutroSafe offers control units for enabling and disabling of detectors, as well as daytime/nighttime units. Available in several language versions. Replace
XX with country code.
Image Part number Description
Number of buttons
For external control
Configurable delay
For AutroSafe only
Ingress Protection level
Notes
116-BW-200/XX Disablement unit 2 ? IP66 Available in Swedish, English and Russian
116-BW-201/XX Disablement unit 0 ? ? IP66 Available in Swedish and English
116-BW-202/XX
Daytime/Nighttime
unit
2 ? ? IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BW-203/XX
Daytime/Nighttime
unit
0 ? ? IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BU-200 Alarm controller unit 2 ? IP66
32 Autronica Fire and Security AS, Petrochemical, Oil & Gas 33
PRODUCTS 2016
Loop units
Detectors
Detectors
AutroSafe offers a wide range of detectors for many different applications, with or without SelfVerify. The following series are available:
? 200 series, standard interactive addressable detectors
? 300 series with SelfVerify, interactive addressable detectors
? 500 series with SelfVerify, interactive addressable detectors for use in hazardous areas
The system also offers Exn- and Exia approved versions of detectors designed for use in high risk applications. S series smoke detectors are specially
designed for applications where high sensitivity is required.
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BD-200M ? ? ? ? IP56
For galleys/cold areas
(-30 oC)
116-BD-501 ? ? ? ? ? ? IP56
116-BD-501/EX ? ? ? ? ? ? ? IP56
116-BD-501/N ? ? ? ? ? ? ? IP56
116-BD-55/XXXEXD ? ? ? ? IP66/67
*
Conventional
116-BD-55/XXXEXDN ? ? ? ? IP66/67
**
Conventional
116-BD-505/140EXD ? ? ? ? ? IP66
60 oC, non-configurable class,
explosion proof
116-BD-505/160EXD ? ? ? ? ? IP66
70 oC, non-configurable class,
explosion proof
116-BD-505/190EXD ? ? ? ? ? IP66
90 oC, non-configurable class,
explosion proof
*: Available with the following alarm temperatures (replace XXX with °F): 140 °F (60 °C), 160 °F (70 °C), 190 °F (90 °C), 225 °F (110 °C),
325 °F (165 °C), 360 °F (180 °C), and 450 °F (230 °C)
**: Available with the following alarm temperatures (replace XXX with °F): 225 °F (110 °C), 275 °F (135 °C), 325 °F (165 °C), 360 °F (180 °C),
and 450 °F (230 °C)
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BDH-300 ? ? ? IP44D
116-BDH-500 ? ? ? ? IP44D
116-BDH-500/EX ? ? ? ? ? IP44D
116-BDH-500/N ? ? ? ? IP44D
116-BHH-300 ? ? ? IP44D
116-BHH-500 ? ? ? ? IP44D
116-BHH-500/EX ? ? ? ? ? IP44D
116-BHH-500/N ? ? ? ? ? IP44D
116-BHH-500/S ? ? ? ? ? IP44D
116-BHH-500/S/EX ? ? ? ? ? ? IP44D
116-BHH-500/S/N ? ? ? ? ? ? IP44D
116-BHH-320 ? ? ? IP44D
116-BHH-520 ? ? ? ? IP44D
116-BHH-520/EX ? ? ? ? ? IP44D
116-BHH-520/N ? ? ? ? ? IP44D
116-5815-021.0001 ? ? ? IP54
Thermostat ATHF-SE-2, 20-150°C
For use in Safe Area or Ex zone 2
Suitable for use in sauna
116-5861-033.0150 ? ? ? ? IP65 SWM-1KL 140°C
34 Autronica Fire and Security AS, Petrochemical, Oil & Gas 35
PRODUCTS 2016
Loop units
Manual call points and release stations
Manual call points and release stations
AutroSafe offers a wide range of manual call points for different applications, every unit features SelfVerify.
Two main series are available:
? 300 series with SelfVerify, interactive addressable manual call points.
? 500 series with SelfVerify, interactive addressable manual call points for use in special environments.
The system features Exn- and Exia approved versions for high risk applications.
All our manual call points can be delivered with a double-action cover.
Image Part number Description
For use in EX areas
For use in EX zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Ingress Protection level*
116-BF-300V2 Manual call point ? IP42D*
116-BF-510WP-H Manual call point ? ? ? IP52*
116-BF-500V2/EX Manual call point ? IP44D*
New design 2016 116-BF-500/N Manual call point ? ? IP44D*
116-BF-501 Manual call point ? ? IP66
116-BF-501/EX Manual call point ? ? ? IP66
116-BF-501/N Manual call point ? ? ? IP66
*: Ingress Protection level, inner housing
Manual call points and release stations (cont.)
Image Part number Description
For use in EX areas
Zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Degree of
protection
116-BF-502 Manual call point ? ? IP66
116-BF-502/EX Manual call point ? ? ? IP66
116-BF-502/N Manual call point ? ? ? IP66
116-BF-503/EX/0100 Manual call point ? ? ? N/A IP66
116-BF-503/N/0100 Manual call point ? ? ? N/A IP66
116-KIT-BF-503/EX/0300 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0300 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/0400 Release station ? ? N/A ? IP66
116-KIT-BF-503/EX/0400 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0400 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/0500 Release station ? ? N/A ? IP66
116-KIT-BF-503/EX/0500 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0500 Release station ? ? ? N/A ? IP66
116-BFG-3/XX
Glass for call point, available in several languages. Replace XX with country code.
No ending = No text
GB = English
GB/AR = English and Arabic
N/GB = Norwegian and English
SU = Russian
36 Autronica Fire and Security AS, Petrochemical, Oil & Gas 37
PRODUCTS 2016
Loop units
Alarm units
*Duty lables
Part number Text Part number Text
116-E-2327/1 Inergen utl?sning | Inergen Release 116-E-2327/26 CO2 Release station
116-E-2327/2 Brannmelder | Fire alarm 116-E-2327/27 CO2 Inhibit station
116-E-2327/3 Water release 116-E-2773/1 Abandon ship
116-E-2327/4 Fire | Brann 116-E-2773/2 Abandon
116-E-2327/5 Vannutl?sning | Water release 116-E-2773/3 Gass | Gas
116-E-2327/6 Inergen press. | Release 116-E-2773/4 Vannt?ke
116-E-2327/7 Vannutl?ser | Water release 116-E-2773/5 ESD 2
116-E-2327/8 Fire Monitor | Water release 116-E-2773/6 CO2 release & inhibit station
116-E-2327/9 Deluge | Water release 116-E-2773/7 VEEUDU K?IVITAMINE
116-E-2327/10 Deluge release 116-E-2773/8 Argonite
116-E-2327/11 Vannt?ke | Water mist 116-E-2773/9 General emergency alarm
116-E-2327/12 Alarm 116-E-2773/10 Argonite Release
116-E-2327/13 Overrisling | Deluge 116-E-2773/11 ESD
116-E-2327/14 Start fire pumps | Старт пожарный насос 116-E-2773/12 Electrical isolation
116-E-2327/15 Vannt?ke | Utl?sning 116-E-2773/13 MCP | Ручной извещатель
116-E-2327/16 Overrisling 116-E-2773/14 ESD AB. OCT.
116-E-2327/17 Fire Push button 116-E-2773/15 CO2 Manual station abort
116-E-2327/18 General Alarm 116-E-2773/16 CO2 Manual station release
116-E-2327/19 FM200 release 116-E-2773/17 Manual alarm call point
116-E-2327/20 FM200 inhibit 116-E-2773/18 Exstinguishant release pushbutton
116-E-2327/21 Fire 116-E-2773/19 East monitor actuation
116-E-2327/22 Water mist release 116-E-2773/20 West monitor actuation
116-E-2327/23 Start Firewater pump 116-E-2773/21 Foam system release
116-E-2327/24 Start Foam skid 116-E-2773/22 Vannutl?ser | Deluge release
116-E-2327/25 Clean Agent release
MEDC manual call points and release stations
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
Alarm units
AutroSafe offers a wide range of alarm units for connection to detection loops or dedicated alarm outputs.
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-BBL-100 Alarm indicator ? ? - 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBL-100/IP Alarm indicator ? ? ? - 2 c IP66
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-7M Alarm bell 6” ? ? 93 – IP55
116-BBR-130
Combined
detector base
and addressable
sounder.
? ? ? 90 – IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-230 Sounder ? ? ? 100 – IP32C
Supported only
by AutroSafe
version 4.3 or
later
*: Candela (c), Joule (j)
**: If loop driver BSD-311 is used, max. no. of units per loop is 40
If loop driver BSD-310 is used, max. no. of units per loop is 21
38 Autronica Fire and Security AS, Petrochemical, Oil & Gas 39
PRODUCTS 2016
Loop units
Alarm units
Alarm units (cont.)
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-BBR-230/IP Sounder ? ? ? ? 100 – IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-130
Base sounder w/
alarm indicator
? ? ? ? 90 2 c IP21C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230
Sounder/alarm
indicator
? ? ? ? 100 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230/IP
Sounder/alarm
indicator
? ? ? ? ? 100 2 c IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BU-47
Conventional
alarm indicator
? ? – – IP30
116-7770-009.0002
Roshni LP, shallow
base
? ? ? ? ?
10-
112
– IP54
*: Candela (c), Joule (j)
Alarm units (cont.)
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-7770-009.0004
Roshni LP, shallow
base
? ? ? ? ? 102 – IP54
116-7770-009.0005 Roshni, deep base ? ? ? ? ? 102 – IP65
116-7780-004.0001
Flashni, shallow
base
? ? ? ? ? 101 0,7 j IP54
116-7780-004.0002 Flashni, deep base ? ? ? ? ? 101 0,7 j IP65
116-7782-001.0003 Sounder ? ? 110 –
IP66
/67
48 VDC
ATEX approval
Ex II 2GD
EExd IIC T5
116-4340-006.0201 Xenon beacon ? ? – 5 j
*: Candela (c), Joule (j)
40 Autronica Fire and Security AS, Petrochemical, Oil & Gas 41
PRODUCTS 2016
Loop units
Alarm units
Alarm units (cont.)
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-4340-006.0924
Solex beacon,
shallow base
? ? ? – 2,5 c IP54
116-4340-006.0925
Solex beacon, deep
base
? ? ? – 2,5 c IP65
116-4340-006.0926
Solex beacon,
shallow base
? ? ? ? – 2,5 c IP54
116-4340-007.0001
Solista LX beacon,
wall mounted ,
deep base
? ? ? ? ? –
W-
2.4-
7.5
IP65 Red flash
116-4340-007.0002
Solista LX beacon,
ceiling mounted,
shallow base
? ? ? ? ? –
C-3-
7.5
IP33C Red flash
116-4340-007.0005
Symphoni LX
WP conventional
base beacon, wall
mounted
? ? ? ? ? ? –
W-
2.4-
7.5
IP66 Red flash
116-7770-009.0040 Symphoni IP66 ? 100 - IP66
For use with 116-
4340-007.0005
*: Candela (c), Joule (j)
Alarm units (cont.)
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-4340-007.0007
Solista LX wall,
shallow base
? ? ? ? ? –
C-3-
7.5
IP33C Red flash
116-4340-007.0008
Symphony G1 LX,
wall
? ? ? ? ? –
W-
2.4-
7.5
IP21C Red flash
116-4340-007.0009
Symphony G1 LX,
wall
? ? ? ? ? –
W-
2.4-
7.5
IP21C Red flash
*: Candela (c), Joule (j)
MEDC beacons, sounders, and combination units
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
42 Autronica Fire and Security AS, Petrochemical, Oil & Gas 43
PRODUCTS 2016
Loop units
Door magnet
Door magnet
Image Part number Description
116-6731-017.0002
Door magnet armature. Type AG w/adjustable socket.
For use with part no: 116-6731-017.0005
116-6731-017.0005
Door holding magnet. GPT, holdpower 650 N, 1 W, 40 mA.
Manual release push button. DNV approved.
For use with part no: 116-6731-017.0002
Accessories for loop units
Image Part number Description
Suitable for EX
installations
116-BWA-100 Base for interactive detector heads, mandatory ?
116-BWB-110
Base adapter for analogue addressable detectors mounted on interactive
loops
116-BWP-100/20 Drip proof conduit box with M20 glands ?
116-BWP-100/25 Drip proof conduit box with holes for M25 glands ?
116-BWP-143A Ventilation duct adapter for smoke detectors, for interactive systems ?
Accessories for loop units (cont.)
Image Part number Description
Suitable for EX
installations
116-BWP-143/SS
Ventilation duct adapter for smoke detectors, for interactive systems.
Stainless steel version for use in harsh environmental conditions, offshore
and onshore.
?
116-BJ-358/100 Pipe kit, L=100 mm ?
116-BJ-358/150 Pipe kit, L=150 mm ?
116-BJ-358/300 Pipe kit, L=300 mm ?
116-BJ-358/550 Pipe kit, L=550 mm ?
116-BJ-358/800 Pipe kit, L=800 mm ?
116-BJ-358/1000 Pipe kit, L=1000 mm ?
116-BWP-145 Heated detector base
116-8142-983.5115 Transformer 230/48 V for up to 10 BWP-45/BWP-145
116-WBW-100 Bypass unit for BWA-100 ?
116-WBW-101 Mounting plate for false ceilings ?
116-BZ-500 Galvanic barrier for Exia approved detectors, for field mounting
116-BZ-500/01 Galvanic barrier for Exia approved detectors, for cabinet mounting
116-4860-011.0100 Polycarbonate cover for manual call point BF-300V2
116-4890-021.0001 Lift flap in polycarbonate for manual call point 116-BF-502, all versions ?
116-4890-021.0010 Lift flap in stainless steel for manual call point 116-BF-502, all versions ?
116-4890-022.0001 Lift flap in polycarbonate for manual call point 116-BF-501, all versions ?
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions ?
116-6571-011.1920
Cable gland M20-1.5 for Ingress Protection level IP67 for I/O units.
NB! Order with 116-6531-006.1920
116-6531-006.1920 Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008 Power base 230 V for Roshni alarm unit
44 Autronica Fire and Security AS, Petrochemical, Oil & Gas 45
PRODUCTS 2016
Loop units
Service tools for detection loops
Accessories for loop units (cont.)
Part number Description
Suitable for EX
installations
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions ?
116-6571-011.1920
Cable gland M20-1.5 for Ingress Protection level IP67 for I/O units.
NB! Order with 116-6531-006.1920
116-6531-006.1920 Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008 Power base 230 V for Roshni alarm unit
Service tools for detection loops
Part number Description
Suitable for EX
installations
116-WAS-2000 AS2000, loop diagnostic tool
116-WBJ-5/01 Test gas dispenser for smoke detectors, excluding pole ?
116-WBJ-5/02 Telescopic pole, 1,26 m to 4,5 m, 1,8 kg ?
116-WBJ-5/03 Expansion pole, 1,13 m. 0,5 kg ?
116-WBJ-5/04 Test gas for smoke detectors ?
116-WBJ-6/01 Heat detector test kit, battery operated, 2 x batteries and charger included (for WBJ-5/02)
116-WBJ-10 Testifire smoke/heat detector test kit (head unit 2 x battery baton and fast charger)
116-WBJ-10/01 Testifire smoke/heat head unit
116-WBJ-10/02 Smoke capsule for WBJ-10 (6 pack)
116-WBJ-10/03 Solo 760 battery baton
116-WBJ-10/04 Solo 725 universal fast battery charger
116-WBJ-140 Installation/extraction tool for AutroSafe detectors ?
46 Autronica Fire and Security AS, Petrochemical, Oil & Gas 47
PRODUCTS 2016
Flame detection
Flame detectors
Protecting life, environment and
property, by any means necessary
Flame detectors
All flame detectors have 4 x M25 cable entries, unless otherwise specified. Swivel mount, glands and blind plugs are not included.
All detectors have an ambient temperature range of -55°C to + 60°C for T6 and -55°C to + 75°C for T5, unless otherwise specified.
Ingress Protection level all detectors and cameras: IP66
Image Part number Description
Stainless steel housing
Aluminium housing
Addressable (built-in BNB-300)
Combination unit with camera av.
For PowerLoop
Cert. -55 °C to +125 °C for T4
With HART protocol
SIL 2 approved
Notes
116-5861-011.4310 AutroFlame X33AF multisp. IR ? ?
SIL 2 available spring
2016
116-5861-011.4320 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4341 AutroFlame X33AF multisp. IR ? ? ?
116-5861-011.4360 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4361 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4373 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4384 AutroFlame X33AF multisp. IR ? ? ? ?
116-5861-011.4385 AutroFlame X33AF multisp. IR ? ? ? ?
116-5861-011.4391 AutroFlame X33AF multisp. IR ? ? ?
116-5861-011.4392 AutroFlame X33AF multisp. IR ? ?
UL Brazil approved
3/4” NPT
116-5861-011.4393 AutroFlame X33AF multisp. IR ? ? ?
116-008279-101 AutroFlame X33AF multisp. IR ? ? ? 3/4” NPT
116-5861-011.4410 AutroFlame X33AF PL multisp. IR ? ?
116-5861-011.4411 AutroFlame X33AF PL multisp. IR ? ? 3/4” NPT
116-5861-011.4420 AutroFlame X33AF PL multisp. IR ? ?
116-5861-011.4440 AutroFlame X33AF PL multisp. IR ? ? ?
116-009009-002 AutroFlame X32AF multisp. IR ?
Hydrogen flame
detection
116-009011-002 AutroFlame X32AF multisp. IR ?
Hydrogen flame
detection
116-5861-011.3980 AutroFlame X98 single IR ? ?
116-5861-011.3981 AutroFlame X98 single IR ? ?
116-009585-001 xWatch surveillance camera ?
For use with any
flame detector above.
M20
PAL video output. For
use in EX areas FM/
CSA approved
768 x 484 px
90° optical lens*
116-009587-001 xWatch surveillance camera ?
*Other lenses available
Autronica’s flame detectors are solutions for applications in which risk to
personnel is high and where fire might result in a large loss of equipment.
Beyond critical life-safety concerns, our products have proven to minimize
total cost of ownership while minimizing false alarms.
Our industrial and commercial applications include oil and gas pipelines,
turbine enclosures, offshore platforms, and Floating Production Storage
and Offloading (FPSO) vessels.
Bottom line – no other company offers more flame-detection technologies
with wider area coverage, higher false-alarm immunity, reduced response
times, and the appropriate global approvals. And to improve ease of use, all
X-Series flame detectors have HART-protocol options.
Flame detection
Keeping a close watch
48 Autronica Fire and Security AS, Petrochemical, Oil & Gas 49
PRODUCTS 2016
Flame detection
Test equipment
Cable glands/Blind plugs
Part number Description
116-6332-032.1925 Blind plug M25, polyamid, Eexe, Ingress Protection level: IP67
116-6530-030.0020 SPMH/NP/M20 blind plug nickle plated brass
116-6530-030.0025 SPMH/NP/M25 blind plug nickle plated brass
116-6571-016.2520 Cable gland adapter M20/M25
116-6571-018.2025 EEXDE adapter M25-20 nickle plated brass
116-6571-070.2025 Cable gland A2LBFM25NP, Brass - nickel plated, Exd/Exe, Ingress Protection level: IP66/68
116-6571-071.2500 Cable gland M25, polyamid, Eexe, Ingress Protection level: IP67
116-6571-080.0001 501/453/UNIV/B M25 nickle plated brass
116-6571-080.0002 501/421/B M25 EEXE nickle plated brass
116-6571-080.0004 501/453/UNIV/OS-M20 nickle plated brass
116-6571-080.0005 501/453/UNIV/O-M20 nickle plated brass
116-6571-080.0006 501/453/UNIV/A-M20 nickle plated brass
116-6571-080.0007 501/421/Os M20 EEXE nickle plated brass
116-6571-080.0008 501/421/O M20 EEXE nickle plated brass
116-6571-080.0009 501/421/A M20 EEXE nickle plated brass
Accessories
Part number Description
116-001680-001 K1003A1006 Window cleaner for flame detectors (6 pcs.)
116-004404-002 Q9001H8001 swivel for xWatch camera SS
116-002099-003 Q9001B1175 swivel for xWatch camera alu.
116-5861-011.9050 Q9033B Swivel mount for AutroFlame detectors, stainless steel
116-5861-011.9051 Q9033A Swivel mount for AutroFlame detectors, aluminium
116-007338-010 Q2033A10R 10 degree field-of-view limiter
116-007338-020 Q2033A20R 20 degree field-of-view limiter
116-007338-030 Q2033A30R 30 degree field-of-view limiter/Weather shield (maintains standard field-of-view)
116-007240-001 Q1116A air shield assembly
116-009199-001 Q1198A dual air shield/flange mount assembly
116-102740-002 Calibration magnet for X series flame detectors
Test equipment
Part number Description
116-006439-004 W8067S Long range test lamp IR/UVIR, (non-EX)
116-004000-006 W867C Portable test lamp 220 V, UV, UV/IR & Single IR
116-007255-001 Q1201C Laser holder for AutroFlame X33AF, UV/IR and UV flame detectors
116-006097-001 Laser aimer (non-EX) for AutroFlame detectors incl. battery
116-009997-001 Charger and battery, for test lamp 116-004000-006
116-007819-001
W6300B Inspector connector for connection to PC utilizing an integral RS485 to RS232 converter
for communication
116-009207-001 Inspector monitor software. To be used together with inspector connector
116-009208-001 O/I replacement kit for AutroFlame X33AF with black reflector plate*
116-010831-001 O/I replacement kit for AutroFlame X33AF with stainless steel reflector plate*
116-009208-002 O/I replacement kit for AutroFlame X22, X52 and X98
116-102740-002 Test magnet for AutroFlame X33AF
116-007739-001 Test magnet and extension pole
*Please note: AutroFlame X33AF models are supplied with either a black or a stainless steel reflector plate. These plates are not interchangeable. Order
the replacement that matches the reflector plate on your AutroFlame X33AF detector.
50 Autronica Fire and Security AS, Petrochemical, Oil & Gas 51
PRODUCTS 2016
Gas detection
Infrared hydrocarbon gas detectors
When it comes to detecting toxic gas would you rather be alerted in 30
seconds... or 5 seconds?
In the demanding environments of the petrochemical oil and gas industry,
fire and gas detection has to deliver optimal results at all times. Autronica
offers traditional detectors with 4-20 mA and/or relay output, but we have
also taken the IR point gas detection a step further. By introducing the
two wire intelligent communication on our IFG PowerLoop we allow for
centralized control of all diagnostic data. Analogue readings and detector
self testing features are available from our AutroPoint IR gas detectors.
The line-of-sight IR gas sensing technology surpasses other alternatives,
both with respect to the life cycle cost as well as operational tangibles of
a more technical nature. Our AutroPath HC800 open path infrared beam
system delivers reliable, combustible gas monitoring for all types of
applications.
The AutroSonic Acoustic Gas Leak Detector hears gas leaks that others
don’t – the instant they occur. It is the first non-contact gas leak detector of
its kind that recognizes unique sound “fingerprints,” analyzing 24 discrete
ultrasonic bands, while ignoring nuisance ultrasonic sources. A highfidelity
microphone continuously monitors for the distinct ultrasound
emitted by pressurized gas leaks across the widest spectrum of frequencies.
With our AutroTox toxic gas detector family, you get a gas detector that
continuously monitors the atmosphere for potentially hazardous gas leaks
and oxygen depletion. An array of sensor models detect a variety of gases
in various concentration ranges.
Autronica delivers the performance, quality, and reliability you can depend
on to keep you safe and satisfied.
Gas detection
When every second counts
Infrared hydrocarbon gas detectors
All units have 4-20 mA with HART protocol and are delivered in stainless steel housing.
Image Part number Description
SIL 2 approved
HART connector
Hydrophobic filter*
Relay output
Cable entries EX approval Notes
116-010195-232
AutroPoint HC200
? 2 x M25 Ex d e
116-5861-011.5100 ? ? 2 x M25 Ex d e
116-010195-233 ? ? 2 x M25 Ex d
116-007168-233 ? ? ? 2 x M25 Ex d
116-010195-234 ? ? 2 x M25 Ex d e
116-007168-234 ? ? ? 2 x M25 Ex d e
116-010195-235 ? ? ? 2 x M25 Ex d
116-007168-235 ? ? ? ? 2 x M25 Ex d
116-010195-236 ? 2 x 3/4” NPT Ex d Inmetro
116-010195-237 ? ? 2 x 3/4” NPT Ex d Inmetro
116-007168-252 ? ? 2 x 3/4” NPT Ex d e
116-5861-011.5300
AutroPoint
HC300PL
? 2 x M25
Ex d e
Addressable,
PowerLoop version
116-5861-011.5301 ? ? 2 x M25
116-010195-030 ? 2 × M25
116-010195-036 2 × M25
116-010195-031 ? 2 × ?’’ NPT
116-010195-037 2 × ?’’ NPT
116-5861-011.5310 ? 2 × ?’’ NPT
116-013800-503
AutroPath HC800
?
M25 Ex d e
5-60 m range
Atex/IECEX
116-013800-553 ?
30-120 m range
Atex/IECEX
116-013801-503 ?
Transmitter spare
Atex/IECEX
116-013802-503 ?
Reciever spare 5-60 m
Atex/IECEX
116-013802-553 ?
Reciever spare 30-120 m
Atex/IECEX
116-013803-503 ?
Transmitter front module
ATEX/IECEX
116-013804-503 ?
Receiver front module
5-60 m
ATEX/IECEX
116-013804-553 ?
Receiver front module
30-120 m
ATEX/IECEX
*: Recommended for areas with high levels of airborne particulates or humidity.
Other detectors available on request.
52 Autronica Fire and Security AS, Petrochemical, Oil & Gas 53
PRODUCTS 2016
Gas detection
Toxic gas detectors
Infrared hydrocarbon gas detectors (cont.)
All units have 4-20 mA with HART protocol and are delivered in stainless steel housing.
Image Part number Description
SIL 2 approved
HART connector
With hydrophobic filter*
With relay output
Cable entries EX approval Notes
116-GD10-P00-17DG-
0XH-00
GD-10P ? ? 2xM20 Ex d e 1 sec. response
116-Z-02104N4011
Searchline Excel IR
gas detector
116-Z-02104NXSSA
With SNX universal
transmitter
*Recommended for areas with high levels of airborne particulates or humidity.
Other detectors available on request.
Acoustic gas detectors
All units have 4-20 ma with HART protocol and are delivered in stainless steel housing.
Image Part number Description
SIL 2 approved
HART connector
With hydrophobic filter*
With relay output
Cable entries EX approval Notes
116-012152-001
AutroSonic acoustic
gas detector kit
? ?
3/4” NPT
Ex d
FM/CSA/ATEX/IECEX
approved.
Kit includes individually
packaged sensor and
116-012153-001 M25 transmitter.
Toxic gas detectors
Autronica provides toxic gas detectors for a wide range of gases. These detectors must be combined with a toxic gas sensor module, listed below. All
display units are Ex d approved, having 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Description
Electrochemical
Stainless steel housing
Aluminium housing
Notes
116-5861-011.6601
AutroTox ATD w/AutroVu AV10 display unit
? ?
SIL 2 approved
116-5861-011.6603 ? ?
Toxic gas sensor modules
Image Part number Description Range
Used with Omicron
point gas detection system
OGS 2.1 (page 67)
Used with Omicron
gas sampling system
OGS 3.1 (page 71)
SIL 2 capable
116-009471-001 GTS H2S 20P 0 – 20 ppm ?
116-009471-002 GTS H2S 50P 0 – 50 ppm ?
116-009471-003 GTS H2S 100P 0 – 100 ppm ?
116-009471-004 GTS Cl2 10P 0 – 10 ppm
116-009471-006 GTS NH3 500P 0 – 500 ppm
116-009471-008 GTS H2 1000P 0 – 1000 ppm ?
116-009471-009 GTS O2 25V 0 – 25 % by volume ? ? ?
116-009471-010 GTS CO 100P 0 – 100 ppm ?
116-009471-011 GTS CO 500P 0 – 500 ppm
116-009471-503 GTS H2S 100PTD, DNV approved 0 – 100 ppm ?
116-009471-509 GTS O2 25VTD, DNV approved 0 – 25 % by volume ?
116-009471-510 GTS CO 100PWD, DNV approved 0 – 100 ppm
116-009471-511 GTS CO 500PWD, DNV approved 0 – 500 ppm
116-009471-532 GTS H2S 50P, DNV approved 0 – 50 ppm ? ?
INMETRO approved versions available
54 Autronica Fire and Security AS, Petrochemical, Oil & Gas 55
PRODUCTS 2016 粉塵濃度檢測探頭 BCJ-Y-C,L=950 4 套 插入深度950mm
Gas detection abb氧化鋯加熱組件 AZ200704
Accessories
Display units
All display units are Ex d approved, having 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Description
Electrochemical
Catalytic combustible
Stainless steel housing
Aluminium housing
SIL 2 approval
Cable entries
Notes
116-011780-001 AutroVu AV10 ? ? ? 5xM25
116-011780-002 AutroVu AV10 ? ? ? 5xM25
116-011780-006 AutroVu AV10 ? ? ? 3/4 NPT
116-011780-081 AutroVu AV10 ? ? ? 3/4 NPT INMETRO (Brazil)
116-011780-082 AutroVu AV10 ? ? ? 3/4 NPT INMETRO (Brazil)
116-011780-003 AutroVu AV10 CGS ? ? 5xM25
116-011780-004 AutroVu AV10 CGS ? ? 5xM25
Toxic gas transmitters and termination boxes
Image Part number Description
Electrochemical
Stainless steel housing
Aluminium housing
Eex d certified
Notes
116-009480-004 GTX Transmitter ? ? ?
Used with Omicron point gas detection
system OGS 2.1 (page <?>) and OGS 3.1
(page 71)
116-226365-601 STB Termination Box ? ? ?
For GT3000, M25, SS, 5 ports
116-226365-603 STB Termination Box ? ? ?
Accessories
Part number Description
116-007525-003 Direct duct mount kit for point gas detectors AutroPoint HC200 and HC300PL
116-009700-001 Magnetic tool for AutroSonic acoustic detector and AutroVu display
116-012513-001 Q912 Duct mount M25 with 1 ft. inlet
116-012513-003 Q912 Duct mount M25 with 3 ft. inlet
116-012513-006 Q912 Duct mount M25 with 3 ft. inlet
116-012513-010 Q912 Duct mount M25 with 10 ft. inlet
116-012513-013 Q912 Duct mount M25 with 13 ft. inlet
116-012673-001 System test film for AutroPath HC800, set of 5 films
116-012287-002 Alignment telescope for AutroPath HC800
116-226365-111 Toxic sensor termination box and separation kit. JBOX, SEP, AL, M20 CENELEC toxic
116-226365-127 Toxic sensor termination box and separation kit. JBOX, SEP, AL, M25 CENELEC Infinity
116-US-843 Rain and sun shield for point gas detectors AutroPoint HC200 and HC300PL
116-Z-475HP1EKL9GMT
Emerson 475 HART communicator. Instrument for calibration of AutroPoint HC200 and
AutroPath HC600 gas detectors. Certified intrinsically safe by CENELEC/ATEX, FM, CSA, FISCO and IECEx
116-Z-GD10-ADAPT1 Duct adapter for point gas detector GD-10P
116-Z-499815712 Sunshade, GD10/PGD10PE
116-Z-ES-244 Gas detector test point
For cable glands and blind plugs, see flame detector section, page 48.
56 Autronica Fire and Security AS, Petrochemical, Oil & Gas 57
PRODUCTS 2016
Gas detection
Calibration kits
Calibration kits
Part number Gas type Concentration Notes
116-006468-001 Methane CH4 50 % LEL AutroPoint HC200/-300
116-007098-005 Hydrogen Sulphide H2S 50 ppm 12 x ampoules, NTMOS detectors
116-010274-001 Hydrogen Sulphide H2S 10 ppm GT3000 series
116-010274-002 Hydrogen Sulphide H2S 25 ppm GT3000 series
116-010274-004 Chlorine Cl2 5 ppm GT3000 series
116-010274-005 Ammonia NH3 50 ppm GT3000 series
116-010274-006 Ammonia NH3 250 ppm GT3000 series
116-010274-008 Hydrogen H2 500 ppm GT3000 series
116-010274-009 Oxygen O2 20,90 % GT3000 series
116-010274-010 Carbon Monoxide CO 50 ppm GT3000 series
116-010274-011 Carbon Monoxide CO 250 ppm GT3000 series
116-010274-013 Sulfur Dioxide SO2 10 ppm GT3000 series
116-010274-014 Sulfur Dioxide SO2 50 ppm GT3000 series
116-225130-005 Hydrogen H2 50 % LEL AutroPoint H2
116-225130-009 Without gas – AutroPoint H2
Accessories for calibration kits
Part number Description
116-004976-001 Calibration cup for catalytic detectors, stainless steel
116-005964-001 Calibration cup for point gas detectors AutroPoint H2S, O2 and TX50
116-006672-002 Windshield calibration bag for AutroPoint HC200/-300
116-225741-001 Extra ampoules for 116-007098-005 NTMOS Calibration Kit H2S Ampoule, 50 ppm
116-227117-001 GT3000 replacement cylinder H2S 50 ppm
116-227117-006 GT3000 replacement cylinder O2 20,90%
116-227117-012 GT3000 replacement cylinder H2S 25 ppm
116-227117-018 GT3000 replacement cylinder H2 500 ppm
116-Z-00670 Step regulator with 0,5 L constant flow
116-Z-00671 Step regulator with 1 L constant flow
116-Z-00678 Carrying case for 2 bottles
116-Z-1200674 2.5 LPM constant flow regulator
116-Z-1711020 Test gas, 65 % LEL methane in N2. 110 L
116-Z-1501020 Test gas, 50 ppm H2S. 110 L
116-Z-1404010 Test gas, 50 % LEL H2. 110 L
116-Z-499810874.8 Sample Flow Housing for point gas detector GD-10P
116-Z-03150 Viton hose pr. meter
116-Z-1200673 Reg. valve 0.3-3.0 L/min